Fairbanks Scales Scb-r9000 Driver For Mac

2020. 1. 25. 03:04카테고리 없음

Fairbanks Scales Scb-r9000 Driver For Mac

Interact Database Transaction Software for Truck Scales PLU Manager Software (Omega Counting Scale) Interact Image Capture Module. Amendment Record Ultegra™ Bench Scale SCB-R9000-14U USB Powered 51222 Manufactured by Fairbanks Scales Inc. 821 Locust Kansas City, Missouri 64106 Created 09/2009 Revision 1 09/2009 New Product Release Revision 2 07/2013 Corrected part numbers, added logos for NTEP, MC, and RoHS.

Fairbanks Scales Scb-r9000 Driver For Mac

Integrating your scale with Stamps.com allows you to place your item on the scale and have its weight automatically uploaded into Stamps.com. This reduces data entry time, avoids errors, and saves money by calculating the exact postage you need. To purchase a scale for use with Stamps.com, please go to the. To learn how to set up your integrated digital scale, click on one of the following links: Installing a USB Scale in the Software To install a supported USB scale in the software:. Launch the software and log in with your username and password. Connect the scale to your computer's USB port and turn it on. The scale's drivers should install automatically.

Click on the Tools menu and select Set Up Digital Scale. From the Digital Scale Selection menu, select your scale and click Install. You should see a message confirming that the installation succeeded.

Your scale is now ready for use with the Stamps.com software. If your scale did not install properly, please. Installing a USB Scale on the Website (Stamps.com Online) To install a supported USB scale in Stamps.com Online:. Connect the scale to your computer's USB port and turn it on.

The scale's drivers should install automatically. Install the Stamps.com plugin by following. This plugin enables Stamps.com to communicate with the scale.

After installing the plugin, you can use any supported USB scale with Stamps.com Online. If your scale did not install properly, please. Installing a Serial Scale in the Software The Stamps.com software supports any serial (RS232) scale using the NCI or 8213 protocols. These scales will need to be configured to work with Stamps.com, which can be done in just a few steps. To do so: First, configure the scale's serial connection with the settings below. Every scale is different, so you may wish to consult your scale's operation manual for instructions on how to do this. The following configuration settings should be used:.

Baud Rate: 9600bps. Data bits: 7. Parity: even.

Stop bits: 1 Your computer port should also be configured to use these settings. To do so:. First, hold down the Windows key on your keyboard and press R. This should open the Run window. In the Run window, type ' devmgmt.msc ' (without quotation marks). Click the OK button.

This should open the Device Manager. Double click on Ports (COM & LPT) to expand it. Right-click on the port your scale will connect to (this is usually Communications Port (COM1) ) and click on Properties. Click on the Port Settings tab.

Scb R9000 14u Driver

Windows

Change the port settings to the following. Bits per second: 9600.

Data bits: 7. Parity: Even. Stop bits: 1.

Fairbanks Scales Scb-r9000 Driver For Mac

Flow control: None. Click OK and close the Device Manager. Finally, the Stamps.com software should be configured to recognize your scale. To do so:. Connect the scale to your computer's serial port. Launch the software and log in with your username and password.

Click on the Tools menu and select Set Up Digital Scale. From the Digital Scale Selection menu, select NCI or 8213 Protocol Serial Scale and click Install. Select the COM port connected to the scale (this is usually COM1) and click Test. You should see a message confirming that the test succeeded. Your scale is now ready for use with the Stamps.com software.

Fairbanks Scale Scb R9000 14u Driver

If your scale did not install properly, please. Programming Scale Buttons Certain Stamps.com integrated scales include function buttons. Each button can be mapped to one of your Favorites. To assign a Favorite to a function button, do the following:. Click on the Tools menu and select Set Up Digital Scale. Install the scale, if you have not done so already. For each button (F1, F2, and F3), select a Favorite from the drop-down list.

If desired, select the Auto Print check box, then click Printer Settings to select the printer settings for that function button. To print postage with a function button: If the selected Favorite does not include a weight value, place the item on the scale, press the associated function button, and press the ENTER button on the scale. (If the selected Favorite does include the weight, you do not need to place the item on the scale.) The Stamps.com software will populate the appropriate postage printing tool with the Favorite settings and the weight from the scale.

If AutoPrint is selected, the Stamps.com software will automatically print the postage without any intervention. Uninstalling a Scale To uninstall a digital scale:. Click on the Tools menu and select Set Up Digital Scale.

Fairbanks Scales Scb-r9000 Driver For Mac Download

From the Digital Scale Selection menu, select your scale and click Uninstall. Your digital scale has now been uninstalled.

Fairbanks Scales Scb-r9000 Driver For Mac